Back to xvmolecular.com
XV Molecular

Document

MSDS-BPC157 · Rev 1.0

Material Safety Data Sheet

Body protecting compound BPC · Pentadecapeptide 157 (stable Arg-salt form)

ProductBPC-157 · 2× L-Arg salt
CAS No.137525-51-0
Issue date2 July 2026
UseResearch use only

1 · General

Product
Pentadecapeptide BPC-157 — stable form (BPC 157 · Arg salt)
Synonyms
Bepecin · BPC-157 · BPC 157 stable form · Pentadecapeptide · Collasan
Sequence
Gly-Glu-Pro-Pro-Pro-Gly-Lys-Pro-Ala-Asp-Asp-Ala-Gly-Leu-Val
Formula
C₆₂H₉₈N₁₆O₂₂
Molecular mass
1419.5
CAS No.
137525-51-0
CB No.
CB81343566
HS Code
38220000

2 · Physical data

Appearance
White amorphous powder
Density
ca. 0.5 g/cm³
Melting point
Decomposition
Explosion limits
None
Flash point
Autoignition temp.
Water solubility
Freely soluble; 1% solution pH 7.3; non-corrosive

3 · Stability & reactivity

Stable. Combustible. Incompatible with acids, bases and oxidising agents. No specific hazards known. Products of thermal decomposition: carbon dioxide, carbon monoxide, nitrogen oxides.

4 · Toxicology

Not toxic and not hazardous according to Directive 67/548/EEC. LD₅₀: not known. Does not belong to the group of antibiotics, hormones or chemotherapeutic compounds.

5 · Fire-fighting measures

Extinguishing agents: water spray, carbon dioxide, dry powder or foam. Special procedures: none needed.

6 · Storage, protection & transport

Storage
< −20°C, protected from light and humidity
Personal protection
Respirator for non-toxic dust, goggles, rubber gloves
Transport
Not dangerous goods — safe for all transport. Stable form: ambient temperature
Ecological information
Data not yet available
Disposal
Incineration

7 · Other information

Pentadecapeptide BPC-157 may be used only for research purposes and is not a medicine or food supplement for human and veterinary use. The above information is believed to be correct but does not purport to be all-inclusive and shall be used only as a guide. XV Molecular shall not be held liable for any damage resulting from handling of, or contact with, the above product.

8 · Acknowledgment of risk & assumption of responsibility

By purchasing, receiving, opening, handling, or otherwise using this product, the buyer, recipient, and every end user (together, the “Researcher”) acknowledges that they have read, understood, and accepted this Safety Data Sheet in full, and expressly agrees to each of the following:

  1. Research use only. The Researcher confirms that this product is a research chemical supplied solely for in-vitro and/or in-vivo laboratory research by qualified professionals. It is not a drug, medicine, dietary supplement, cosmetic, food, or medical device; it is not sterile or pyrogen-free; and it is not for human or veterinary use, consumption, ingestion, inhalation, injection, or administration of any kind.
  2. Qualification and competence. The Researcher represents and warrants that they are of legal age, are a qualified researcher or research institution, and are competent to receive and handle research chemicals safely, and that the product will be handled only by trained personnel using appropriate protective equipment and laboratory controls.
  3. Assumption of all risk. The Researcher voluntarily and knowingly assumes all risks of every kind arising from or connected with the product — including its purchase, receipt, transport, storage, handling, use, misuse, and disposal — whether those risks are known or unknown, foreseen or unforeseen. The product is supplied strictly “as is” and “with all faults,” with no warranty of any kind, whether express or implied, including any implied warranty of merchantability, fitness for a particular purpose, safety, or non-infringement.
  4. Sole responsibility and legal compliance. The Researcher accepts sole and complete responsibility for the safe and lawful receipt, handling, use, and disposal of the product, and for determining and complying with all laws, regulations, licences, and institutional requirements that apply in their jurisdiction — including those governing import, export, possession, handling, use, and disposal. XV Molecular makes no representation that the product is lawful in the Researcher’s jurisdiction.
  5. Release and indemnification. To the fullest extent permitted by law, the Researcher releases and forever discharges XV Molecular and its owners, officers, employees, suppliers, and agents from any and all claims, liabilities, damages, losses, costs, and expenses (including reasonable legal fees) arising from or related to the product, and agrees to indemnify and hold them harmless against any such claim brought by the Researcher or by any third party.
  6. Limitation of liability. XV Molecular shall not be liable for any direct, indirect, incidental, consequential, special, or punitive damages of any kind arising from or related to the product, even if advised of the possibility of such damages. Nothing in this acknowledgment excludes or limits any liability that cannot be excluded or limited under applicable law.
  7. Acceptance or return. If the Researcher does not accept these terms in full, they must not open or use the product and must return it unused and intact. Opening, handling, or using the product constitutes full and irrevocable acceptance of this acknowledgment.

Caution

BPC-157 products are not for human or veterinary use and may be harmful if used. These products are for research use only and are not sterile or pyrogen-free.

None of our products are designed for human or veterinary consumption and are deemed unsafe until further research. This product is not intended to prevent, treat, or cure any disease or to affect the structure or function of the body. This product is not for human or veterinary consumption and may be harmful if ingested or introduced into humans or animals. Keep out of reach of children.

Issued by

XV Molecular

See also: Certificate of Analysis